Temperature and Pressure Dependent Curves Dialog
Applicability: Cranium, Synapse (core versions 0315+)

Curves drawn through data values and estimates can greatly help visual trends in values and help organize values at different state conditions or from different sources.

The Temperature and Pressure Dependent Section uses the Curve Points Dialog to add and edit curve points. The dialog is activated by clicking the left mouse button on the section's curve points table control or by selecting the Edit Values command from the section's curve points table control commands menu. (See Curve Points Commands Menu documentation for details.)

Dialog Controls

The Curves dialog provides controls for editing curve points, assigning curve names, and sorting values.

1
Table Control: displays the current list of curve points. Each row contains a temperature value, presure value, datum value and, optionally, the name of the curve to which the curve point is assigned. (If a curve point is not assigned to a curve then it is automatically assigned to the 'default curve'.) Clicking the left mouse button on a table row selects that table row. Clicking and holding the left mouse button down and then dragging the mouse will select several table rows. Double-clicking the left mouse button on a row selects the row and edits the contents of that row.
2
Edit Button: activates the Curve Points dialog enabling you to enter state variables and source information. See below for documentation.
3
Commands Button: pressing the dialog's Commands button or clicking the right mouse button on the table control displays the commands menu. This menu provides standard commands for copying, pasting, and clearing curve points. See the documentation on Common Menu Commands for details.
4
Set Comment: prompts for a comment to be assigned to all selected curve points.
5
Set Curve: prompts for a curve name to be assigned to all selected curve points.
6
Sort Button: the dialog's Sort button will be enabled if two or more rows are selected. Pressing the Sort button activates the Sort Attribute dialog. This dialog enables you to sort curve points in ascending or descending order by the selected attribute.
7
Add Rows Button: pressing the Add Rows button will add rows to the bottom of the table control.
Commands Menu

Clicking the right mouse button within the table control or pressing the dialog's Commands button displays the curve points commands menu.

The menu's commands enable you to copy, cut and paste values to and from the table control. See Common Menu Commands for documentation on the commands commonly found on command menus.

Curve Point Dialog

Clicking the left mouse button on a row in the table control or selecting a row and pressing the Edit button, activates the Curve Point Edit Dialog. The dialog enables you to enter values for state variables and supporting information.

1
Temperature Control: enables you to enter the curve point's temperature.
2
Units Control: enables you specify the units in which the temperature was entered.
3
Pressure Control: enables you to enter the curve point's pressure.
4
Units Control: enables you specify the units in which the pressure was entered.
5
Value Control: enables you to enter the curve point's value for the physical property being edited.
6
Units Control: enables you specify the units in which the physical property value was entered.
7
Curve Name Control: enables you to enter the name of the curve containing this point.
8
Previous Button: inserts the previous curve points curve name, if present, into this dialog's curve name control. Using the Previous button is helpful to ensure consistency when entering a series of curve points.
9
Comments Control: the Comments control enables you to enter general information to better describe the entered value. Very often comments document the date of entry, the name of the person who entered the value, or assumptions about the entered value.
10
Date, Phrase, Set Buttons: these buttons provide standard operations to help you enter comments. Pressing the Date button inserts the current date and time into the comment control. Pressing the Phrase button inserts the stored 'common phrase' into the comment control. Pressing the Set button enables you to change the 'common phrase'. (See documentation on the Set Phrase dialog for details.
Tip: Regression points make good curve points

It is very common to use the Regression capabilities of data and estimates dialogs to generate points for the fitted equations. The points generated from these regressions can be pasted, typically with the help of the scratch pad, into the Phase Equilibria Curves Dialog. See documenation on the Regress Values Dialog for details.

Related Documentation
Topic Description
Getting Started using Synapse provides a quick tour of Synapse's capabilities including examples of chemical product design.
Getting Started using Cranium provides a quick tour of Cranium's capabilities including a discussion of structure editing.
Estimating Chemical Properties a short video demonstrating how to estimate the physical properties of chemicals using either Synapse or Cranium.
Estimating Mixture Properties a short video demonstrating how to estimate the physical properties of mixtures using either Synapse or Cranium.